Strona 1 - PULSA GLM

PULSA GLM® MECHANICAL DIAPHRAGM METERING PUMP Bulletin #: IOM-GLM-DM7-001 Installation, Operation & Maintenance Instruction Models: GLM7

Strona 2 - Safety Considerations:

10 6.3 Oil Fill and Maintenance 6.3.1 Oil Capacities It is recommended that adequate supplies of PULSALube oil be on hand for periodic changes an

Strona 3 - Table of Contents

11 6.3.3 Oil Changes The recommended oil change intervals are dependent upon the operating environment and level of pump usage, classified as follo

Strona 4 - 2. Principles of Operation

12 6. Start the pump at the zero stroke length setting and slowly increase the setting to 100 to prime the pump. If this does not work, it will be

Strona 5 - 2.3 Gear Ratio Assembly

13 6.5 Calibration Figure 7, sample flow calibration curve All metering pumps must be calibrated to accurately specify stroke length settings fo

Strona 6 - 5. Installation

14 7. Maintenance BEFORE PERFORMING ANY MAINTENANCE REQUIRING REAGENT HEAD OR VALVE (WET END) DISASSEMBLY, BE SURE TO RELIEVE PRESSURE FROM THE PI

Strona 7 - 5.2 Piping System

15 Figure 8, wet end components GLM® DM7 diaphragms do not have a specific cycle life; however, the accumulation of foreign material or debris

Strona 8

16 7.1 Diaphragm Removal & Reinstallation 1. Adjust the stroke setting to 0% and disconnect the power source to the drive motor. 2. Re

Strona 9 - 6. Equipment Startup

17 6. Remove all but one top reagent head bolt. Product will leak out between the pump head adaptor and reagent head as the bolts are loosened. 7

Strona 10 - 6.3.2 Gearbox Oil Fill

18 12. Thread the diaphragm (clockwise) fully onto the shaft. When reinstalling a used diaphragm it is not necessary to maintain the previous orient

Strona 11 - 6.3.3 Oil Changes

19 7.3 Check Valves Most fluid metering problems are related to check valves. Problems usually stem from solids accumulation between valve and sea

Strona 12 - Figure 6, process

2 Pulsafeeder Factory Service Policy Should you experience a problem with your Pulsafeeder pump, first consult the troubleshooting guide in your ope

Strona 13 - 6.5 Calibration

20 7.4 Check Valve Removal & Reinstallation, Plastic Union-Nut type 1. Disconnect the power source to the drive motor. 2. Relieve all press

Strona 14 - 7. Maintenance

21 7.5 Check Valve Removal and Reinstallation, Metal Tie-Bar type 1. Disconnect the power source to the drive motor. 2. Relieve all pressure f

Strona 15

22 Figure 14, Check valves, metal construction

Strona 16

23 7.6 Motor Removal & Reinstallation 1. Disconnect the power source to the drive motor. 2. Disconnect the motor wiring from the motor. 3.

Strona 17

24 8. Replacement Parts 8.1 KOPkit Program GLM® DM7 KOPkits contain all replacement parts normally used in a preventative maintenance program. (P

Strona 18 - 7.2 Diaphragm Shaft Seal

25 8.3 KOPkit numbers by model: Pump Model Wetted Material Connection Type KOPkit number DM7 Polypropylene NPT / ISO / FLG KD7P DM7 31 6

Strona 19 - 7.3 Check Valves

26 10. Troubleshooting DIFFICULTY PROBABLE CAUSE REMEDY Pump does not start Faulty power source Check power source Blown fuse, circuit break

Strona 20

27 DIFFICULTY PROBABLE CAUSE REMEDY Delivery erratic Leak in suction line Locate and correct Product cavitating Increase suction pressur

Strona 21

28 11. Piping Accessories Pressure Relief Valves Pressure relief valves are designed to protect chemical feed systems from damage that may be cause

Strona 22

29 12. Dimensional Drawings

Strona 23

3 Table of Contents 1. INTRODUCTION ...

Strona 25 - 8.3 KOPkit numbers by model:

31 13. Parts Diagrams and Parts Lists

Strona 27

PULSA GLM® MECHANICAL DIAPHRAGM METERING PUMP Bulletin #: IOM-GLM-DM7-001 A unit of IDEX Corporation 2883 Brighton Henrietta Town Line Roa

Strona 28 - 11. Piping Accessories

4 1. Introduction The GLM® DM7 metering pump is positive displacement, mechanically operated reciprocating diaphragm pump. Each pump consists of a

Strona 29 - 12. Dimensional Drawings

5 2.1 Reagent Head Assembly The typical reagent head assembly consists of reagent head, diaphragm, and suction and discharge cartridge check valves

Strona 30

6 3. Equipment Inspection Check all equipment for completeness against the order and for any evidence of shipping damage. Shortages or damage must

Strona 31

7 5.2 Piping System 1. All systems should include a pressure relief valve on the discharge side, to protect piping and process equipment, includin

Strona 32

8 5.4 Discharge Pressure Requirements All GLM® DM7 metering pumps are designed for continuous service at the rated discharge pressure. If system suc

Strona 33

9 6. Equipment Startup 6.1 Fastener Inspection All pump fasteners should be checked prior to pump operation, and occasionally during use. This wo